"id": "CVE-2021-34598",
|
|
"sourceIdentifier": "info@cert.vde.com",
|
|
"published": "2021-11-10T12:15:16.160",
|
|
"lastModified": "2022-07-28T09:34:04.833",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "In Phoenix Contact FL MGUARD 1102 and 1105 in Versions 1.4.0, 1.4.1 and 1.5.0 the remote logging functionality is impaired by the lack of memory release for data structures from syslog-ng when remote logging is active"
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "En Phoenix Contact FL MGUARD 1102 y 1105 en las versiones 1.4.0, 1.4.1 y 1.5.0, la funcionalidad remote logging est\u00e1 afectada por una falta de liberaci\u00f3n de memoria para las estructuras de datos de syslog-ng cuando el registro remoto est\u00e1 activo"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "info@cert.vde.com",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.5,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 3.6
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "MEDIUM",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "PARTIAL",
|
|
"baseScore": 4.3
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 8.6,
|
|
"impactScore": 2.9,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "info@cert.vde.com",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-401"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-401"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:phoenixcontact:fl_mguard_1102_firmware:1.4.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "AA1C71EF-C44F-4661-83AA-B65B704AE0B4"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:phoenixcontact:fl_mguard_1102_firmware:1.4.1:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "1819CD97-D92F-42A0-B8DB-C13D0B8D93B2"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:phoenixcontact:fl_mguard_1102_firmware:1.5.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "EF940FF8-56F3-40CB-B978-78C1F0985E87"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:phoenixcontact:fl_mguard_1102:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "093DE0FB-96BE-4971-A6A5-6404F02CB6CB"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:phoenixcontact:fl_mguard_1105_firmware:1.4.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "97534DA1-F536-454B-8ABD-B251A7B4AB9D"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:phoenixcontact:fl_mguard_1105_firmware:1.4.1:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "FE12A61D-73FD-423D-B7E5-C43EE7E4FC71"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:phoenixcontact:fl_mguard_1105_firmware:1.5.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "BD02E727-CC42-4965-BC35-23CF0B63338F"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:phoenixcontact:fl_mguard_1105:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "E72161DC-0AC0-4603-A0CB-73940B951D66"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert.vde.com/en/advisories/VDE-2021-046/",
|
|
"source": "info@cert.vde.com",
|
|
"tags": [
|
|
"Third Party Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |