René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

190 lines
6.6 KiB
JSON

{
"id": "CVE-2022-25788",
"sourceIdentifier": "psirt@autodesk.com",
"published": "2022-04-19T21:15:18.650",
"lastModified": "2022-04-28T15:56:51.253",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A maliciously crafted JT file in Autodesk AutoCAD 2022 may be used to write beyond the allocated buffer while parsing JT files. This vulnerability can be exploited to execute arbitrary code."
},
{
"lang": "es",
"value": "Un archivo JT malicioso en Autodesk AutoCAD versi\u00f3n 2022 puede usarse para escribir m\u00e1s all\u00e1 del b\u00fafer asignado mientras son analizados los archivos JT. Esta vulnerabilidad puede ser explotada para ejecutar c\u00f3digo arbitrario"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2022",
"versionEndExcluding": "2022.1.2",
"matchCriteriaId": "E1BE9431-DC86-4ABB-8EE2-9FADA3B0AEBA"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:autocad:*:*:*:*:*:-:*:*",
"versionStartIncluding": "2022",
"versionEndExcluding": "2022.1.2",
"matchCriteriaId": "E3116E10-FB93-4EC7-957E-B130FE5153BF"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:autocad:*:*:*:*:*:macos:*:*",
"versionStartIncluding": "2022",
"versionEndExcluding": "2022.2.2",
"matchCriteriaId": "8357611C-929E-407C-B4C8-6ED926E513C6"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2022",
"versionEndExcluding": "2022.1.2",
"matchCriteriaId": "E9466EE6-83C9-492F-8486-F3E6C1DD9F5A"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2022",
"versionEndExcluding": "2022.1.2",
"matchCriteriaId": "6DD91E39-A3D8-4806-A778-608FD6C29BB2"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:-:*:*",
"versionStartIncluding": "2022",
"versionEndExcluding": "2022.1.2",
"matchCriteriaId": "0DC17B10-E6E8-4D49-BDEF-DBC5097580C9"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:macos:*:*",
"versionStartIncluding": "2022",
"versionEndExcluding": "2022.2.2",
"matchCriteriaId": "EEC464C9-D741-41B4-B460-B4305BCD83FA"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2022",
"versionEndExcluding": "2022.1.2",
"matchCriteriaId": "120326C3-E212-4341-A25D-BC3DD50CF228"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2022",
"versionEndExcluding": "2022.1.2",
"matchCriteriaId": "B117299A-C5FE-419F-9C1C-DF58A2772055"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2022",
"versionEndExcluding": "2022.1.2",
"matchCriteriaId": "CC178212-E440-46E9-9F00-60A5516D4D72"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2022",
"versionEndExcluding": "2022.1.2",
"matchCriteriaId": "7ED0DB1D-6F37-4C1B-B55E-42F3A4E34299"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2022",
"versionEndExcluding": "2022.1.2",
"matchCriteriaId": "82C21398-6A86-4E56-A98E-E80FFCC6732E"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:inventor:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2022",
"versionEndExcluding": "2022.2",
"matchCriteriaId": "D53B7E4C-4F2E-428D-A6CB-D4F2FB5865B0"
}
]
}
]
}
],
"references": [
{
"url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0002",
"source": "psirt@autodesk.com",
"tags": [
"Vendor Advisory"
]
}
]
}