2023-11-14 13:00:21 +00:00

112 lines
4.5 KiB
JSON

{
"id": "CVE-2023-38073",
"sourceIdentifier": "productcert@siemens.com",
"published": "2023-09-12T10:15:28.113",
"lastModified": "2023-11-14T11:15:09.660",
"vulnStatus": "Modified",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20826)"
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones &lt; V14.3.0.1), Teamcenter Visualization V13.3 (Todas las versiones &lt; V13.3.0.12), Teamcenter Visualization V14.0 (Todas las versiones), Teamcenter Visualization V14.1 ( Todas las versiones &lt; V14.1.0.11), Teamcenter Visualization V14.2 (todas las versiones &lt; V14.2.0.6), Teamcenter Visualization V14.3 (todas las versiones &lt; V14.3.0.1). La aplicaci\u00f3n afectada contiene una vulnerabilidad de Confusi\u00f3n de Tipos al analizar archivos WRL. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-20826)"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-843"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*",
"versionEndExcluding": "14.3.0.1",
"matchCriteriaId": "2ABFF8F6-AB75-4EB4-AA59-D297EA29B4D1"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"versionStartIncluding": "13.3.0",
"versionEndExcluding": "13.4.0.12",
"matchCriteriaId": "88242224-85E8-4F7B-8AF3-D5CFDBE741BE"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"versionStartIncluding": "14.0",
"versionEndExcluding": "14.1.0.11",
"matchCriteriaId": "B0A2FCDD-F71A-4AE1-B969-55B7A0D0DF0D"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"versionStartIncluding": "14.2",
"versionEndExcluding": "14.2.0.6",
"matchCriteriaId": "7E1EFF45-5311-4E89-B736-271EF3C0C232"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"versionStartIncluding": "14.3",
"versionEndExcluding": "14.3.0.1",
"matchCriteriaId": "5F7641A6-5EF6-4258-A7E0-87CC180B30F0"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf",
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf",
"source": "productcert@siemens.com"
}
]
}