mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 17:21:36 +00:00
119 lines
3.6 KiB
JSON
119 lines
3.6 KiB
JSON
{
|
|
"id": "CVE-2007-5397",
|
|
"sourceIdentifier": "PSIRT-CNA@flexerasoftware.com",
|
|
"published": "2008-02-28T20:44:00.000",
|
|
"lastModified": "2024-11-21T00:37:48.480",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Heap-based buffer overflow in the activePDF Server service (aka APServer.exe) in activePDF Server 3.8.4 and 3.8.5.14, and possibly other versions before 3.8.6.16, allows remote attackers to execute arbitrary code via a packet with a size field that is less than the actual size of the data."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Desbordamiento de b\u00fafer basado en mont\u00edculo en el servicio activePDF Server (tambi\u00e9n conocido como APServer.exe) en activePDF Server 3.8.4 y 3.8.5.14, y posiblemente versiones anteriores a 3.8.6.16, que permite a atacantes remotos ejecutar c\u00f3digo de su elecci\u00f3n a trav\u00e9s de un paquete con un tama\u00f1o de campo que es menor que el tama\u00f1o de datos actual."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
|
|
"baseScore": 7.5,
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "PARTIAL",
|
|
"integrityImpact": "PARTIAL",
|
|
"availabilityImpact": "PARTIAL"
|
|
},
|
|
"baseSeverity": "HIGH",
|
|
"exploitabilityScore": 10.0,
|
|
"impactScore": 6.4,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-119"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:activepdf:server:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "3.8.4",
|
|
"matchCriteriaId": "8AF42C71-D2FD-4EDF-BD1C-59BBC1CADA65"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:activepdf:server:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "3.8.5.14",
|
|
"matchCriteriaId": "D4ADBD30-69D0-47D2-A030-42BCD0BC7A62"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "http://secunia.com/advisories/27371",
|
|
"source": "PSIRT-CNA@flexerasoftware.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "http://secunia.com/secunia_research/2007-87/advisory/",
|
|
"source": "PSIRT-CNA@flexerasoftware.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "http://www.securityfocus.com/bid/28013",
|
|
"source": "PSIRT-CNA@flexerasoftware.com"
|
|
},
|
|
{
|
|
"url": "http://secunia.com/advisories/27371",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "http://secunia.com/secunia_research/2007-87/advisory/",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "http://www.securityfocus.com/bid/28013",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108"
|
|
}
|
|
]
|
|
} |