mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 09:11:28 +00:00
129 lines
3.5 KiB
JSON
129 lines
3.5 KiB
JSON
{
|
|
"id": "CVE-2024-33180",
|
|
"sourceIdentifier": "cve@mitre.org",
|
|
"published": "2024-07-16T16:15:04.767",
|
|
"lastModified": "2024-11-21T09:16:36.113",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/saveParentControlInfo."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se descubri\u00f3 que Tenda AC18 V15.03.3.10_EN contiene una vulnerabilidad de desbordamiento del b\u00fafer basada en pila a trav\u00e9s del par\u00e1metro deviceId en ip/goform/saveParentControlInfo."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseScore": 9.8,
|
|
"baseSeverity": "CRITICAL",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 5.9
|
|
},
|
|
{
|
|
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseScore": 9.8,
|
|
"baseSeverity": "CRITICAL",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-787"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-120"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:tendacn:ac18_firmware:15.03.3.10:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "330A6DE5-8F04-492C-B167-0071ACDBF7AC"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:tendacn:ac18:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "FCF0F551-6E6C-48D6-9C2A-740B84AF0349"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://palm-vertebra-fe9.notion.site/saveParentControlInfo_1-7c9695d0251945ae8006db705b9b80ac",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Exploit"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://palm-vertebra-fe9.notion.site/saveParentControlInfo_1-7c9695d0251945ae8006db705b9b80ac",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Exploit"
|
|
]
|
|
}
|
|
]
|
|
} |