"id": "CVE-2022-3156",
|
|
"sourceIdentifier": "PSIRT@rockwellautomation.com",
|
|
"published": "2022-12-27T19:15:10.357",
|
|
"lastModified": "2023-01-06T14:34:21.267",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A remote code execution vulnerability exists in Rockwell Automation Studio 5000 Logix Emulate software. Users are granted elevated permissions on certain product services when the software is installed. Due to this misconfiguration, a malicious user could potentially achieve remote code execution on the targeted software."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 5.9
|
|
},
|
|
{
|
|
"source": "PSIRT@rockwellautomation.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-287"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "PSIRT@rockwellautomation.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-287"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:rockwellautomation:studio_5000_logix_emulate:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "20.011",
|
|
"versionEndExcluding": "34.00",
|
|
"matchCriteriaId": "FB9EB8A2-A2F2-45A4-923E-2E40BDF16F76"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137846",
|
|
"source": "PSIRT@rockwellautomation.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |