"id": "CVE-2022-33923",
|
|
"sourceIdentifier": "security_alert@emc.com",
|
|
"published": "2022-07-21T04:15:12.987",
|
|
"lastModified": "2022-07-30T01:17:29.330",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Dell PowerStore, versions prior to 3.0.0.0, contains an OS Command Injection vulnerability in PowerStore T environment. A locally authenticated attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS command on the PowerStore underlying OS. Exploiting may lead to a system take over by an attacker."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Dell PowerStore, versiones anteriores a 3.0.0.0, contiene una vulnerabilidad de inyecci\u00f3n de comandos del Sistema Operativo en el entorno PowerStore T. Un atacante autenticado localmente podr\u00eda potencialmente explotar esta vulnerabilidad, conllevando a una ejecuci\u00f3n de un comando de SO arbitrario en el SO subyacente de PowerStore. La explotaci\u00f3n puede conllevar a una toma de control del sistema por parte de un atacante"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 5.9
|
|
},
|
|
{
|
|
"source": "security_alert@emc.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "HIGH",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 6.4,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 0.5,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-78"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "security_alert@emc.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-78"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:dell:emc_powerstore_500t_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "3.0.0.0-1732745",
|
|
"matchCriteriaId": "6E7999B2-9790-43D7-A231-0206A36AEC3C"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:dell:emc_powerstore_500t:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "2F396420-8007-401C-985E-436C227B42A9"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:dell:emc_powerstore_1200t_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "3.0.0.0-1732745",
|
|
"matchCriteriaId": "761D6F6E-D4BF-4B83-8EED-19DF784BB223"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:dell:emc_powerstore_1200t:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "FB705779-4464-447D-BFB6-63073FFC026F"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:dell:emc_powerstore_3200t_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "3.0.0.0-1732745",
|
|
"matchCriteriaId": "191F6EDA-88C2-4C18-89B5-0D6200FD15CE"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:dell:emc_powerstore_3200t:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "C19A09B3-64C4-4FBF-91DA-782E117FD0F2"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:dell:emc_powerstore_5200t_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "3.0.0.0-1732745",
|
|
"matchCriteriaId": "428A51ED-C8B5-4FC0-84E2-D74D2B3F7447"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:dell:emc_powerstore_5200t:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "E67E33BD-8D23-4B30-83A6-B2105ACF5EFC"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:dell:emc_powerstore_9200t_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "3.0.0.0-1732745",
|
|
"matchCriteriaId": "5BD1DB6E-CB42-4A67-98D6-23F0E88BDEE5"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:dell:emc_powerstore_9200t:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "20FD2CBE-D0CE-442C-B961-E8DE951A4645"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.dell.com/support/kbdoc/000201283",
|
|
"source": "security_alert@emc.com",
|
|
"tags": [
|
|
"Patch",
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |