"id": "CVE-2023-49722",
|
|
"sourceIdentifier": "psirt@bosch.com",
|
|
"published": "2024-01-09T10:15:20.720",
|
|
"lastModified": "2024-11-21T08:33:44.630",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Network port 8899 open in WiFi firmware of BCC101/BCC102/BCC50 products, that allows an attacker to connect to the device via same WiFi network."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "El puerto de red 8899 est\u00e1 abierto en el firmware WiFi de los productos BCC101/BCC102/BCC50, que permite a un atacante conectarse al dispositivo a trav\u00e9s de la misma red WiFi."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "psirt@bosch.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
|
|
"baseScore": 8.3,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "ADJACENT_NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 5.5
|
|
},
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
|
|
"baseScore": 6.5,
|
|
"baseSeverity": "MEDIUM",
|
|
"attackVector": "ADJACENT_NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "NONE"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 3.6
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "psirt@bosch.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-1125"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "NVD-CWE-Other"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:bosch:bcc101_firmware:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "4.13.20",
|
|
"versionEndExcluding": "4.13.33",
|
|
"matchCriteriaId": "DBDA6413-E7A3-4566-9F04-4B7AB937EB4C"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:bosch:bcc101:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "F914736C-5826-4A7A-A7E1-97553D324F6B"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:bosch:bcc102_firmware:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "4.13.20",
|
|
"versionEndExcluding": "4.13.33",
|
|
"matchCriteriaId": "790AE7CC-DB71-4F39-ADB2-665FEF22AEB5"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:bosch:bcc102:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "1B1DB812-82C4-415E-A79E-A3464C3FAA03"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:bosch:bcc50_firmware:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "4.13.20",
|
|
"versionEndExcluding": "4.13.33",
|
|
"matchCriteriaId": "0CEEF136-27E9-49F6-A6CB-DC6AE02964A7"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:bosch:bcc50:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "E3DCAF6D-ED0D-4242-870B-13C63FC69082"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-473852.html",
|
|
"source": "psirt@bosch.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-473852.html",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |