2024-07-14 02:06:08 +00:00

192 lines
5.1 KiB
JSON

{
"id": "CVE-2020-16839",
"sourceIdentifier": "cve@mitre.org",
"published": "2021-07-30T14:15:13.263",
"lastModified": "2022-07-12T17:42:04.277",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "On Crestron DM-NVX-DIR, DM-NVX-DIR80, and DM-NVX-ENT devices before the DM-XIO/1-0-3-802 patch, the password can be changed by sending an unauthenticated WebSocket request."
},
{
"lang": "es",
"value": "En los dispositivos Crestron DM-NVX-DIR, DM-NVX-DIR80 y DM-NVX-ENT anteriores al parche DM-XIO/1-0-3-802, la contrase\u00f1a puede ser cambiada mediante el env\u00edo de una petici\u00f3n WebSocket no autenticada"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"availabilityImpact": "NONE",
"baseScore": 5.0
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:crestron:dm-nvx-dir-80:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1EE8C233-ED65-4C48-B47B-2A3F527D6B36"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:crestron:dm-nvx-dir-80_firmware:1.0.1.788:*:*:*:*:*:*:*",
"matchCriteriaId": "15C1E995-7ED6-41B5-8CBB-6997CBE39606"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:crestron:dm-nvx-dir-160:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E91B3A82-FC1A-4FBB-9989-5603D0314BC6"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:crestron:dm-nvx-dir-160_firmware:1.0.1.788:*:*:*:*:*:*:*",
"matchCriteriaId": "1ECBD70E-3468-4E20-9426-9AC3BC9B69FA"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:crestron:dm-nvx-dir-ent:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B546575C-524E-48F8-AD0B-E0A35DC0A5DC"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:crestron:dm-nvx-dir-ent_firmware:1.0.1.788:*:*:*:*:*:*:*",
"matchCriteriaId": "8B3016A1-3D7B-4C8A-8F99-E3B5BF3269B1"
}
]
}
]
}
],
"references": [
{
"url": "https://support.crestron.com",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://www.crestron.com/Security/Security-at-Crestron",
"source": "nvd@nist.gov",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://www.crestron.com/Software-Firmware/Firmware/DigitalMedia/DM-XIO/1-0-3-802",
"source": "cve@mitre.org",
"tags": [
"Permissions Required"
]
},
{
"url": "https://www.security.crestron.com",
"source": "cve@mitre.org",
"tags": [
"Broken Link"
]
}
]
}