"id": "CVE-2024-10498",
|
|
"sourceIdentifier": "cybersecurity@se.com",
|
|
"published": "2025-01-17T11:15:08.340",
|
|
"lastModified": "2025-01-17T11:15:08.340",
|
|
"vulnStatus": "Awaiting Analysis",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that\ncould allow an unauthorized attacker to modify configuration values outside of the normal range when the\nattacker sends specific Modbus write packets to the device which could result in invalid data or loss of web\ninterface functionality."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "CWE-119: Existe una vulnerabilidad de restricci\u00f3n incorrecta de operaciones dentro de los l\u00edmites de un b\u00fafer de memoria que podr\u00eda permitir que un atacante no autorizado modifique valores de configuraci\u00f3n fuera del rango normal cuando el atacante env\u00eda paquetes de escritura Modbus espec\u00edficos al dispositivo, lo que podr\u00eda generar datos no v\u00e1lidos o p\u00e9rdida de la funcionalidad de la interfaz web."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV40": [
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "4.0",
|
|
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
|
|
"baseScore": 6.9,
|
|
"baseSeverity": "MEDIUM",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"attackRequirements": "NONE",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"vulnConfidentialityImpact": "NONE",
|
|
"vulnIntegrityImpact": "LOW",
|
|
"vulnAvailabilityImpact": "LOW",
|
|
"subConfidentialityImpact": "NONE",
|
|
"subIntegrityImpact": "NONE",
|
|
"subAvailabilityImpact": "NONE",
|
|
"exploitMaturity": "NOT_DEFINED",
|
|
"confidentialityRequirement": "NOT_DEFINED",
|
|
"integrityRequirement": "NOT_DEFINED",
|
|
"availabilityRequirement": "NOT_DEFINED",
|
|
"modifiedAttackVector": "NOT_DEFINED",
|
|
"modifiedAttackComplexity": "NOT_DEFINED",
|
|
"modifiedAttackRequirements": "NOT_DEFINED",
|
|
"modifiedPrivilegesRequired": "NOT_DEFINED",
|
|
"modifiedUserInteraction": "NOT_DEFINED",
|
|
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
|
|
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
|
|
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
|
|
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
|
|
"modifiedSubIntegrityImpact": "NOT_DEFINED",
|
|
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
|
|
"Safety": "NOT_DEFINED",
|
|
"Automatable": "NOT_DEFINED",
|
|
"Recovery": "NOT_DEFINED",
|
|
"valueDensity": "NOT_DEFINED",
|
|
"vulnerabilityResponseEffort": "NOT_DEFINED",
|
|
"providerUrgency": "NOT_DEFINED"
|
|
}
|
|
}
|
|
],
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
|
|
"baseScore": 6.5,
|
|
"baseSeverity": "MEDIUM",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "LOW",
|
|
"availabilityImpact": "LOW"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 2.5
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-119"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-08&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-014-08.pdf",
|
|
"source": "cybersecurity@se.com"
|
|
}
|
|
]
|
|
} |