"id": "CVE-2023-27464",
|
|
"sourceIdentifier": "productcert@siemens.com",
|
|
"published": "2023-04-11T10:15:18.223",
|
|
"lastModified": "2023-04-19T19:59:34.863",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in Mendix Forgot Password (Mendix 7 compatible) (All versions < V3.7.1), Mendix Forgot Password (Mendix 8 compatible) (All versions < V4.1.1), Mendix Forgot Password (Mendix 9 compatible) (All versions < V5.1.1). The affected versions of the module contain an observable response discrepancy issue that could allow an attacker to retrieve sensitive information."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 5.3,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 1.4
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-203"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-204"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:mendix:forgot_password:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "3.7.1",
|
|
"matchCriteriaId": "3C89CB05-677F-421D-8B89-3E0BFF89EE4B"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:mendix:forgot_password:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "4.0.0",
|
|
"versionEndExcluding": "4.1.1",
|
|
"matchCriteriaId": "7E439E0B-C5B9-4686-9258-D23A8CB75AAE"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:mendix:forgot_password:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "5.0.0",
|
|
"versionEndExcluding": "5.1.1",
|
|
"matchCriteriaId": "7D8F298E-CF76-44EB-96D3-67DF5E0ABEF4"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-699404.pdf",
|
|
"source": "productcert@siemens.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |