"id": "CVE-2020-13591",
"sourceIdentifier": "talos-cna@cisco.com",
"published": "2021-04-09T18:15:13.023",
"lastModified": "2023-02-03T21:55:28.933",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "An exploitable SQL injection vulnerability exists in the \"access_rules/rules_form\" page of the Rukovoditel Project Management App 2.7.2. A specially crafted HTTP request can lead to SQL injection. An attacker can make an authenticated HTTP request to trigger this vulnerability, this can be done either with administrator credentials or through cross-site request forgery."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad de inyecci\u00f3n SQL explotable en la p\u00e1gina \"access_rules/rules_form\" de la Rukovoditel Project Management App versi\u00f3n 2.7.2. Una petici\u00f3n HTTP especialmente dise\u00f1ada puede conllevar a una inyecci\u00f3n SQL. Un atacante puede llevar a cabo una petici\u00f3n HTTP autenticada para desencadenar esta vulnerabilidad, esto puede ser realizado con credenciales de administrador o mediante un ataque de tipo cross-site request forgery"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
],
"cvssMetricV30": [
{
"source": "talos-cna@cisco.com",
"type": "Secondary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:L/A:N",
"attackVector": "NETWORK",
"attackComplexity": "HIGH",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 2.2,
"impactScore": 2.7
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
},
{
"source": "talos-cna@cisco.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:rukovoditel:rukovoditel:2.7.2:*:*:*:*:*:*:*",
"matchCriteriaId": "56C3B146-C89C-4E90-806F-A9A49F0FEC99"
}
]
}
]
}
],
"references": [
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1200",
"source": "talos-cna@cisco.com",
"tags": [
"Exploit",
"Third Party Advisory"
]
}
]
}