René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

117 lines
3.6 KiB
JSON

{
"id": "CVE-2020-25232",
"sourceIdentifier": "productcert@siemens.com",
"published": "2020-12-14T21:15:19.987",
"lastModified": "2020-12-16T17:44:18.183",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Due to the usage of an insecure random number generation function and a deprecated cryptographic function, an attacker could extract the key that is used when communicating with an affected device on port 8080/tcp."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en LOGO!&#xa0;8 BM (incluyendo variantes SIPLUS) (Todas las versiones anteriores a V8.3).&#xa0;Debido al uso de una funci\u00f3n de generaci\u00f3n de n\u00fameros aleatorios no segura y una funci\u00f3n criptogr\u00e1fica obsoleta, un atacante podr\u00eda extraer la clave que es usada cuando se comunica con un dispositivo afectado en el puerto 8080/tcp"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-327"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:siemens:logo\\!_8_bm_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "8.3",
"matchCriteriaId": "2FA7BA89-3BF0-4C68-AC47-951B1F11F96D"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:siemens:logo\\!_8_bm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "59947FF6-3711-47C1-B91E-87DBF31DAF57"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480824.pdf",
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
]
}
]
}