2024-12-08 03:06:42 +00:00

112 lines
3.2 KiB
JSON

{
"id": "CVE-2024-6796",
"sourceIdentifier": "productsecurity@baxter.com",
"published": "2024-09-09T20:15:05.470",
"lastModified": "2024-09-20T14:53:11.447",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated attacker to gain unauthorized access to Connex portal's database and/or modify content."
},
{
"lang": "es",
"value": "En el portal de salud Baxter Connex publicado antes del 30/8/2024, se encontr\u00f3 una vulnerabilidad de control de acceso inadecuado que podr\u00eda permitir que un atacante no autenticado obtenga acceso no autorizado a la base de datos del portal Connex y/o modifique el contenido."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "productsecurity@baxter.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 3.9,
"impactScore": 4.2
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 3.9,
"impactScore": 5.2
}
]
},
"weaknesses": [
{
"source": "productsecurity@baxter.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:baxter:connex_health_portal:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2024-08-30",
"matchCriteriaId": "21E3F634-BFB7-4605-91ED-E03F8EA2E7C4"
}
]
}
]
}
],
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-249-01",
"source": "productsecurity@baxter.com",
"tags": [
"Third Party Advisory",
"US Government Resource"
]
}
]
}