2024-12-08 03:06:42 +00:00

161 lines
5.0 KiB
JSON

{
"id": "CVE-2020-27007",
"sourceIdentifier": "productcert@siemens.com",
"published": "2021-02-09T17:15:14.407",
"lastModified": "2024-11-21T05:20:40.273",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of HPG files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to access data in the context of the current process. (ZDI-CAN-12207)"
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.1.0.1), Teamcenter Visualization (Todas las versiones anteriores a V13.1.0.1).&#xa0;Las aplicaciones afectadas carecen de una comprobaci\u00f3n apropiada de los datos suministrados por el usuario al analizar archivos HPG.&#xa0;Esto podr\u00eda resultar en un acceso a la memoria m\u00e1s all\u00e1 del final de un b\u00fafer asignado.&#xa0;Un atacante podr\u00eda explotar esta vulnerabilidad para acceder a los datos en el contexto del proceso actual.&#xa0;(ZDI?CAN-12207)"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"baseScore": 4.3,
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"availabilityImpact": "NONE"
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*",
"versionEndExcluding": "13.1.0.1",
"matchCriteriaId": "4FB80DF8-5E85-4072-8999-02EDA895A112"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"versionEndExcluding": "13.1.0.1",
"matchCriteriaId": "0EB3193F-54C0-4678-A22D-A98D2134F9E7"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf",
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-233/",
"source": "productcert@siemens.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
]
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-234/",
"source": "productcert@siemens.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-233/",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
]
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-234/",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
]
}
]
}