"id": "CVE-2020-3302",
"sourceIdentifier": "psirt@cisco.com",
"published": "2020-05-06T17:15:13.073",
"lastModified": "2024-11-26T16:09:02.407",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the web UI of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to overwrite files on the file system of an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by uploading a crafted file to the web UI on an affected device. A successful exploit could allow the attacker to overwrite files on the file system of the affected device."
},
{
"lang": "es",
"value": "Una vulnerabilidad en la Interfaz de Usuario web del Cisco Firepower Management Center (FMC) Software, podr\u00eda permitir a un atacante remoto autenticado sobrescribir archivos en el sistema de archivos de un dispositivo afectado. La vulnerabilidad es debido a una comprobaci\u00f3n de entrada insuficiente. Un atacante podr\u00eda explotar esta vulnerabilidad al cargar un archivo dise\u00f1ado en la Interfaz de Usuario web sobre un dispositivo afectado. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir a un atacante sobrescribir archivos en el sistema de archivos del dispositivo afectado."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.2
}
],
"cvssMetricV30": [
{
"source": "psirt@cisco.com",
"type": "Secondary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "HIGH",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.6,
"impactScore": 5.2
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:C/A:C",
"baseScore": 8.5,
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "NONE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE"
},
"baseSeverity": "HIGH",
"exploitabilityScore": 8.0,
"impactScore": 9.2,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "psirt@cisco.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.2.2.2",
"matchCriteriaId": "EE66CA02-37AA-4530-9C0A-219E5296A814"
}
]
}
]
}
],
"references": [
{
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmcai-z5dQObVN",
"source": "psirt@cisco.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmcai-z5dQObVN",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}