2024-12-08 03:06:42 +00:00

290 lines
8.7 KiB
JSON

{
"id": "CVE-2020-6966",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"published": "2020-01-24T18:15:12.723",
"lastModified": "2024-11-21T05:36:24.143",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilize a weak encryption scheme for remote desktop control, which may allow an attacker to obtain remote code execution of devices on the network."
},
{
"lang": "es",
"value": "En ApexPro Telemetry Server Versiones 4.2 y anteriores, CARESCAPE Telemetry Server Versiones v4.2 y anteriores, Clinical Information Center (CIC) Versiones 4.X y 5.X, CARESCAPE Central Station (CSCS) Versiones 1.X, los productos afectados usan un esquema de cifrado d\u00e9bil para el control de escritorio remoto, lo que puede permitir a un atacante obtener la ejecuci\u00f3n de c\u00f3digo remota de los dispositivos sobre la red."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 6.0
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"baseScore": 10.0,
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE"
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-326"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-326"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:gehealthcare:apexpro_telemetry_server_firmware:*:*:*:*:*:*:*:*",
"versionEndIncluding": "4.2",
"matchCriteriaId": "4C5DD75E-7D4D-4B05-A84D-EDEAA2D23E59"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:gehealthcare:apexpro_telemetry_server:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A94476A1-B004-4561-918D-C41631F36D9F"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mai700_firmware:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "28F6C17B-2288-4EA1-B89F-6E1FED96ADD1"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:gehealthcare:carescape_central_station_mai700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4C2C8D13-A1C6-4DD1-9886-F925E2158C3A"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mas700_firmware:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "85D5EF4C-F118-4CA9-93C1-6366303F8893"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:gehealthcare:carescape_central_station_mas700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "42991B9E-1D70-4A40-A283-162F2A73669B"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100d_firmware:4.0:*:*:*:*:*:*:*",
"matchCriteriaId": "2FE710E0-76E4-4F7E-890C-9AEB00F5DB13"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100d_firmware:5.0:*:*:*:*:*:*:*",
"matchCriteriaId": "68B32A68-64CF-4579-B465-F1B8F4997C48"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:gehealthcare:clinical_information_center_mp100d:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D0E93396-C7BB-4E53-8921-8251DC6A0F75"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100r_firmware:4.0:*:*:*:*:*:*:*",
"matchCriteriaId": "57D4B8E4-C481-446C-BF46-6FB6253344A1"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100r_firmware:5.0:*:*:*:*:*:*:*",
"matchCriteriaId": "71F1DE32-2C25-4C0C-A4BF-30F5F3F19C70"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:gehealthcare:clinical_information_center_mp100r:-:*:*:*:*:*:*:*",
"matchCriteriaId": "057C6A3F-BD7E-4655-B9D9-1402C5259D59"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:gehealthcare:carescape_telemetry_server_mp100r_firmware:*:*:*:*:*:*:*:*",
"versionEndIncluding": "4.2",
"matchCriteriaId": "E7A592B9-9BE4-4096-B733-EE9A03D7A610"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:gehealthcare:carescape_telemetry_server_mp100r:-:*:*:*:*:*:*:*",
"matchCriteriaId": "636B9839-E067-4BB0-A5FF-F3B4BE12AB50"
}
]
}
]
}
],
"references": [
{
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01",
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
]
},
{
"url": "https://www3.gehealthcare.com/~/media/downloads/us/support/site-planning/site-readiness/gehc-gateway_project_implementation_guide_pdf.pdf",
"source": "nvd@nist.gov",
"tags": [
"Product"
]
},
{
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
]
}
]
}