"id": "CVE-2020-7523",
|
|
"sourceIdentifier": "cybersecurity@se.com",
|
|
"published": "2020-08-31T17:15:12.373",
|
|
"lastModified": "2024-11-21T05:37:18.530",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se presenta una vulnerabilidad de Administraci\u00f3n de Privilegios Inapropiada en Schneider Electric Modbus Serial Driver (consulte la notificaci\u00f3n de seguridad para las versiones) que podr\u00eda causar una escalada de privilegios locales cuando el servicio Modbus Serial Driver es invocado. El controlador no asigna, modifica, rastrea o comprueba apropiadamente los privilegios de un actor, creando una esfera de control no prevista para ese actor"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "HIGH",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "CHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.1,
|
|
"impactScore": 6.0
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P",
|
|
"baseScore": 4.4,
|
|
"accessVector": "LOCAL",
|
|
"accessComplexity": "MEDIUM",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "PARTIAL",
|
|
"integrityImpact": "PARTIAL",
|
|
"availabilityImpact": "PARTIAL"
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 3.4,
|
|
"impactScore": 6.4,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-269"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:schneider-electric:modbus_driver_suite:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "14.15.0.0",
|
|
"matchCriteriaId": "105D5959-C658-4129-9723-01CCF48F5BD1"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:schneider-electric:modbus_serial_driver:*:*:*:*:*:*:x86:*",
|
|
"versionEndExcluding": "2.20_ie_30",
|
|
"matchCriteriaId": "1DA63BCF-FB96-4226-8325-4A38D08F9E3A"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:schneider-electric:modbus_serial_driver:*:*:*:*:*:*:x64:*",
|
|
"versionEndExcluding": "3.20_ie_30",
|
|
"matchCriteriaId": "B242EE94-A9A0-482D-ADB6-D6CC6608703E"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/",
|
|
"source": "cybersecurity@se.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |