2024-07-14 02:06:08 +00:00

64 lines
2.8 KiB
JSON

{
"id": "CVE-2023-39468",
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"published": "2024-05-03T03:15:12.563",
"lastModified": "2024-05-03T12:50:12.213",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of DbasSectorFileToExecuteOnReset parameter. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20799."
},
{
"lang": "es",
"value": "Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo de funci\u00f3n peligrosa expuesta. Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. Se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad. La falla espec\u00edfica existe en el manejo del par\u00e1metro DbasSectorFileToExecuteOnReset. El problema se debe a una funci\u00f3n peligrosa expuesta. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto de SYSTEM. Era ZDI-CAN-20799."
}
],
"metrics": {
"cvssMetricV30": [
{
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-749"
}
]
}
],
"references": [
{
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new",
"source": "zdi-disclosures@trendmicro.com"
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1036/",
"source": "zdi-disclosures@trendmicro.com"
}
]
}