René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

139 lines
4.9 KiB
JSON

{
"id": "CVE-2022-1118",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"published": "2022-05-17T20:15:08.173",
"lastModified": "2022-05-26T01:39:57.080",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited"
},
{
"lang": "es",
"value": "Connected Components Workbench (versiones v13.00.00 y anteriores), ISaGRAF Workbench (versiones v6.0 hasta v6.6.9), y Safety Instrumented System Workstation (versiones v1.2 y anteriores (para Trusted Controllers)) no limitan los objetos que pueden ser deserializados. Esto permite a atacantes dise\u00f1ar un objeto serializado malicioso que, si es abierto por un usuario local en Connected Components Workbench, puede resultar en una ejecuci\u00f3n de c\u00f3digo arbitrario. Esta vulnerabilidad requiere la interacci\u00f3n del usuario para ser explotada con \u00e9xito"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
},
{
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 6.0
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
]
},
"weaknesses": [
{
"source": "ics-cert@hq.dhs.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-502"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:rockwellautomation:connected_component_workbench:*:*:*:*:*:*:*:*",
"versionEndIncluding": "13.00.00",
"matchCriteriaId": "68034639-8E86-45CE-97EA-AAC8EAEE6600"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:rockwellautomation:isagraf_workbench:*:*:*:*:*:*:*:*",
"versionStartIncluding": "6.0",
"versionEndIncluding": "6.6.9",
"matchCriteriaId": "54E95041-485F-48A3-A3C3-AA59F74EF64E"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:rockwellautomation:safety_instrumented_systems_workstation:*:*:*:*:*:*:*:*",
"versionEndIncluding": "1.2",
"matchCriteriaId": "0CDC3A7A-94B0-4B10-B478-C8C9E1FAD73C"
}
]
}
]
}
],
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-095-01",
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
]
}
]
}