René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

106 lines
3.3 KiB
JSON

{
"id": "CVE-2022-24314",
"sourceIdentifier": "cybersecurity@se.com",
"published": "2022-02-09T23:15:19.840",
"lastModified": "2022-02-16T03:06:43.520",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)"
},
{
"lang": "es",
"value": "Una CWE-125: Se presenta una vulnerabilidad de Lectura Fuera de L\u00edmites que podr\u00eda causar p\u00e9rdidas de memoria que podr\u00edan resultar en una denegaci\u00f3n de servicio cuando un atacante env\u00eda repetidamente un mensaje especialmente dise\u00f1ado. Producto afectado: Interactive Graphical SCADA System Data Server (versiones V15.0.0.22020 y anteriores)"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "cybersecurity@se.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:interactive_graphical_scada_system_data_server:*:*:*:*:*:*:*:*",
"versionEndIncluding": "15.0.0.22020",
"matchCriteriaId": "6418CE35-66F8-4EA4-9C84-4396FF70C773"
}
]
}
]
}
],
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-01",
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Vendor Advisory"
]
}
]
}