René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

137 lines
4.0 KiB
JSON

{
"id": "CVE-2022-24422",
"sourceIdentifier": "security_alert@emc.com",
"published": "2022-05-26T16:15:08.113",
"lastModified": "2022-06-07T17:07:01.157",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Dell iDRAC9 versions 5.00.00.00 and later but prior to 5.10.10.00, contain an improper authentication vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability to gain access to the VNC Console."
},
{
"lang": "es",
"value": "Dell iDRAC9 versiones de 5.00.00.00 y posteriores, pero anteriores a 5.10.10.00, contienen una vulnerabilidad de autenticaci\u00f3n inapropiada. Un atacante remoto no autenticado puede explotar esta vulnerabilidad para conseguir acceso a la consola VNC"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
},
{
"source": "security_alert@emc.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 2.8,
"impactScore": 6.0
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
},
{
"source": "security_alert@emc.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:dell:idrac9:*:*:*:*:*:*:*:*",
"versionStartIncluding": "5.00.00.00",
"versionEndExcluding": "5.10.10.00",
"matchCriteriaId": "B2CC8B5B-1C7D-4760-BA05-D1C538E12C01"
}
]
}
]
}
],
"references": [
{
"url": "https://www.dell.com/support/kbdoc/en-us/000199267/dsa-2022-068-dell-idrac9-security-update-for-an-improper-authentication-vulnerability",
"source": "security_alert@emc.com",
"tags": [
"Patch",
"Vendor Advisory"
]
}
]
}