René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

157 lines
4.6 KiB
JSON

{
"id": "CVE-2022-26007",
"sourceIdentifier": "talos-cna@cisco.com",
"published": "2022-05-12T17:15:10.523",
"lastModified": "2022-05-23T17:22:12.707",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "An OS command injection vulnerability exists in the console factory functionality of InHand Networks InRouter302 V3.5.4. A specially-crafted network request can lead to command execution. An attacker can send a sequence of requests to trigger this vulnerability."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad de inyecci\u00f3n de comandos del Sistema Operativo en la funcionalidad console factory de InHand Networks InRouter302 versi\u00f3n V3.5.4. Una petici\u00f3n de red especialmente dise\u00f1ada puede conllevar a una ejecuci\u00f3n de un comando. Un atacante puede enviar una secuencia de peticiones para desencadenar esta vulnerabilidad"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9
}
],
"cvssMetricV30": [
{
"source": "talos-cna@cisco.com",
"type": "Secondary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 2.3,
"impactScore": 6.0
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0
},
"baseSeverity": "HIGH",
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
},
{
"source": "talos-cna@cisco.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:inhandnetworks:ir302_firmware:3.5.4:*:*:*:*:*:*:*",
"matchCriteriaId": "4A1EDABA-8613-4349-B7B7-3ABF9C913D86"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:inhandnetworks:ir302:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0E358655-E442-4D2C-B0B8-03C6780EC55C"
}
]
}
]
}
],
"references": [
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1475",
"source": "talos-cna@cisco.com",
"tags": [
"Exploit",
"Technical Description",
"Third Party Advisory"
]
},
{
"url": "https://www.inhandnetworks.com/upload/attachment/202205/10/InHand-PSA-2022-01.pdf",
"source": "talos-cna@cisco.com",
"tags": [
"Vendor Advisory"
]
}
]
}