"id": "CVE-2022-30234",
"sourceIdentifier": "cybersecurity@se.com",
"published": "2022-06-02T23:15:07.560",
"lastModified": "2022-06-13T15:47:13.033",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)"
},
{
"lang": "es",
"value": "Una CWE-798: Se presenta una vulnerabilidad en el Uso de Credenciales Embebidas que podr\u00eda permitir la ejecuci\u00f3n de c\u00f3digo arbitrario cuando es obtenido acceso a nivel root. Productos afectados: Wiser Smart, EER21000 y EER21001 (versiones V4.5 y anteriores)"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
},
{
"source": "cybersecurity@se.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "LOW",
"baseScore": 9.4,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.5
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "cybersecurity@se.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-798"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21000_firmware:*:*:*:*:*:*:*:*",
"versionEndIncluding": "4.5",
"matchCriteriaId": "5FF54835-9F49-417D-985F-24799D9B93A0"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E5552670-EDA0-4C30-B292-2228FB418A38"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21001_firmware:*:*:*:*:*:*:*:*",
"versionEndIncluding": "4.5",
"matchCriteriaId": "B3E7CC55-F222-470E-AA71-DEECB4A971F6"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21001:-:*:*:*:*:*:*:*",
"matchCriteriaId": "68D3AC8F-AA3E-4173-89FB-6F8EA59FA52B"
}
]
}
]
}
],
"references": [
{
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/",
"source": "cybersecurity@se.com",
"tags": [
"Mitigation",
"Vendor Advisory"
]
}
]
}