mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-29 01:31:20 +00:00
110 lines
3.0 KiB
JSON
110 lines
3.0 KiB
JSON
{
|
|
"id": "CVE-2022-34446",
|
|
"sourceIdentifier": "security_alert@emc.com",
|
|
"published": "2023-02-11T01:23:24.780",
|
|
"lastModified": "2023-11-07T03:48:42.020",
|
|
"vulnStatus": "Modified",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "\nPowerPath Management Appliance with versions 3.3 & 3.2* contains Authorization Bypass vulnerability. An authenticated remote user with limited privileges (e.g., of role Monitoring) can exploit this issue and gain access to sensitive information, and modify the configuration.\n\n\n\n\n\n"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 8.1,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 5.2
|
|
},
|
|
{
|
|
"source": "security_alert@emc.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "NVD-CWE-Other"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "security_alert@emc.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-285"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:dell:powerpath_management_appliance:3.2:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "D92273A9-3C81-4082-9550-DC1497AEDF39"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:dell:powerpath_management_appliance:3.3:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "8AD7DBFF-1187-4F94-A3A4-95D52E6B3DC4"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.dell.com/support/kbdoc/000205404",
|
|
"source": "security_alert@emc.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |