2025-03-27 17:03:53 +00:00

86 lines
3.8 KiB
JSON

{
"id": "CVE-2025-2098",
"sourceIdentifier": "cvd@cert.pl",
"published": "2025-03-26T16:15:23.540",
"lastModified": "2025-03-27T16:45:27.850",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Fast CAD Reader application on MacOS was found to be installed with incorrect file permissions (rwxrwxrwx). This is inconsistent with standard macOS security practices, where applications should have drwxr-xr-x permissions. Incorrect permissions allow for Dylib Hijacking. Guest account, other users and applications can exploit this vulnerability for privilege escalation. This issue affects Fast CAD Reader\u00a0in possibly all versions since the vendor has not responded to our messages. The tested version was 4.1.5"
},
{
"lang": "es",
"value": "Se detect\u00f3 que la aplicaci\u00f3n Fast CAD Reader en macOS se instal\u00f3 con permisos de archivo incorrectos (rwxrwxrwx). Esto contradice las pr\u00e1cticas de seguridad est\u00e1ndar de macOS, donde las aplicaciones deben tener permisos drwxr-xr-x. Los permisos incorrectos permiten el secuestro de Dylib. Las cuentas de invitado, otros usuarios y aplicaciones pueden explotar esta vulnerabilidad para la escalada de privilegios. Este problema afecta a Fast CAD Reader posiblemente en todas las versiones, ya que el proveedor no ha respondido a nuestros mensajes. La versi\u00f3n probada fue la 4.1.5."
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "cvd@cert.pl",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirement": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"availabilityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
]
},
"weaknesses": [
{
"source": "cvd@cert.pl",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-266"
}
]
}
],
"references": [
{
"url": "https://apps.apple.com/pl/app/fast-cad-reader/id1484905765",
"source": "cvd@cert.pl"
},
{
"url": "https://cert.pl/en/posts/2025/03/CVE-2025-2098/",
"source": "cvd@cert.pl"
}
]
}