2025-03-16 03:03:50 +00:00

94 lines
3.4 KiB
JSON

{
"id": "CVE-2025-22368",
"sourceIdentifier": "csirt@divd.nl",
"published": "2025-03-11T14:15:24.627",
"lastModified": "2025-03-11T14:15:24.627",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS."
},
{
"lang": "es",
"value": "El comando de firmware SCU autenticado del firmware para Mennekes Smart / Premium Chargingpoints se puede utilizar de forma indebida para la ejecuci\u00f3n de comandos porque los comandos del SO se neutralizan incorrectamente cuando ciertos campos se pasan al SO subyacente."
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "csirt@divd.nl",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:Y/R:X/V:X/RE:X/U:X",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirement": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"availabilityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"Safety": "NEGLIGIBLE",
"Automatable": "YES",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
]
},
"weaknesses": [
{
"source": "csirt@divd.nl",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-78"
},
{
"lang": "en",
"value": "CWE-250"
}
]
}
],
"references": [
{
"url": "https://csirt.divd.nl/CVE-2025-22368",
"source": "csirt@divd.nl"
},
{
"url": "https://csirt.divd.nl/DIVD-2025-00003",
"source": "csirt@divd.nl"
},
{
"url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf",
"source": "csirt@divd.nl"
}
]
}