"id": "CVE-2023-28829",
"sourceIdentifier": "productcert@siemens.com",
"published": "2023-06-13T09:15:16.707",
"lastModified": "2023-06-13T09:15:16.707",
"vulnStatus": "Received",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions < V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms & Events)) were used per default. These\r\nservices were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "HIGH",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "LOW",
"baseScore": 3.9,
"baseSeverity": "LOW"
},
"exploitabilityScore": 0.5,
"impactScore": 3.4
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-477"
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508677.pdf",
"source": "productcert@siemens.com"
}
]
}