"id": "CVE-2020-26920",
|
|
"sourceIdentifier": "cve@mitre.org",
|
|
"published": "2020-10-09T07:15:17.683",
|
|
"lastModified": "2020-10-16T18:52:51.637",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects SRK60 before 2.5.3.110, SRR60 before 2.5.3.110, and SRS60 before 2.5.3.110."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a SRK60 versiones anteriores a 2.5.3.110, SRR60 versiones anteriores a 2.5.3.110 y SRS60 versiones anteriores a 2.5.3.110"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "ADJACENT_NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 5.9
|
|
},
|
|
{
|
|
"source": "cve@mitre.org",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "ADJACENT_NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 5.9
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
|
|
"accessVector": "ADJACENT_NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "PARTIAL",
|
|
"integrityImpact": "PARTIAL",
|
|
"availabilityImpact": "PARTIAL",
|
|
"baseScore": 5.8
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 6.5,
|
|
"impactScore": 6.4,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-77"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:srk60_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "2.5.3.110",
|
|
"matchCriteriaId": "CDCF7F02-4BFA-4DA3-AA1A-C15289B50AFF"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:srk60:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "DCC347EB-699E-4626-A944-2D378101DDCF"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:srr60_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "2.5.3.110",
|
|
"matchCriteriaId": "89140957-E138-457B-9DC9-1C2D65650F48"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:srr60:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "55E6F589-04DA-431C-9E03-BA2A59BB0E4A"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:srs60_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "2.5.3.110",
|
|
"matchCriteriaId": "97F1A2A9-D055-4887-A708-A6B5AA3CABE6"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:srs60:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "BFB01247-A20F-41CA-8718-E8E60E7F14B3"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://kb.netgear.com/000062333/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0327",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |