"id": "CVE-2024-23802",
|
|
"sourceIdentifier": "productcert@siemens.com",
|
|
"published": "2024-02-13T09:15:49.000",
|
|
"lastModified": "2024-02-13T19:22:31.803",
|
|
"vulnStatus": "Analyzed",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones < V2201.0012), Tecnomatix Plant Simulation V2302 (Todas las versiones < V2302.0006). Las aplicaciones afectadas contienen una lectura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada mientras analizan archivos SPP especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-125"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "2201.0012",
|
|
"matchCriteriaId": "92315B86-671A-48F9-9D7D-C638DABD8520"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "2302.0",
|
|
"versionEndExcluding": "2302.0006",
|
|
"matchCriteriaId": "D222D65A-C271-4BE4-8139-DB5F38D053D5"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/html/ssa-017796.html",
|
|
"source": "productcert@siemens.com",
|
|
"tags": [
|
|
"Mitigation",
|
|
"Patch",
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |