"id": "CVE-2024-2705",
"sourceIdentifier": "cna@vuldb.com",
"published": "2024-03-20T17:15:07.750",
"lastModified": "2024-06-18T20:15:12.870",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Una vulnerabilidad fue encontrada en Tenda AC10U 1.0/15.03.06.49 y clasificada como cr\u00edtica. La funci\u00f3n formSetQosBand del archivo /goform/SetNetControlList es afectada por esta vulnerabilidad. La manipulaci\u00f3n de la lista de argumentos provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador de esta vulnerabilidad es VDB-257456. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "cna@vuldb.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "cna@vuldb.com",
"type": "Secondary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0
},
"baseSeverity": "HIGH",
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "cna@vuldb.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
}
],
"references": [
{
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formSetQosBand.md",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?ctiid.257456",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.257456",
"source": "cna@vuldb.com"
}
]
}