mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 09:11:28 +00:00
138 lines
4.4 KiB
JSON
138 lines
4.4 KiB
JSON
{
|
|
"id": "CVE-2024-37036",
|
|
"sourceIdentifier": "cybersecurity@se.com",
|
|
"published": "2024-06-12T17:15:50.637",
|
|
"lastModified": "2024-08-14T14:19:37.137",
|
|
"vulnStatus": "Analyzed",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass\nwhen sending a malformed POST request and particular configuration parameters are set."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "CWE-787: Existe una vulnerabilidad de escritura fuera de los l\u00edmites que podr\u00eda provocar una omisi\u00f3n de autenticaci\u00f3n al enviar una solicitud POST con formato incorrecto y se establecen par\u00e1metros de configuraci\u00f3n particulares."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 9.8,
|
|
"baseSeverity": "CRITICAL"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 5.9
|
|
},
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 9.8,
|
|
"baseSeverity": "CRITICAL"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-787"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:sage_rtu_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "c3414-500-s02k5_p8",
|
|
"matchCriteriaId": "F3A29B28-4959-4156-B77A-5D38B896029B"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "02E606BD-92F8-4396-AD13-666D76E1E34D"
|
|
},
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "97E29CCC-4E21-411E-80DD-545A66E9B042"
|
|
},
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "66759867-027F-4FA6-ABA6-BFDEE49E8F8D"
|
|
},
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "AA561E2A-4787-48D7-ABBB-26D0D7D24E6F"
|
|
},
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "453696F2-0F4C-4000-A438-F814D0FC3504"
|
|
},
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "6462B366-8F9F-49D6-939A-E73C1D5A707C"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-05.pdf",
|
|
"source": "cybersecurity@se.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |