"id": "CVE-2024-3904",
|
|
"sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
|
|
"published": "2024-07-04T09:15:04.317",
|
|
"lastModified": "2024-07-23T01:15:09.063",
|
|
"vulnStatus": "Awaiting Analysis",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Incorrect Default Permissions vulnerability in Smart Device Communication Gateway preinstalled on MELIPC Series MI5122-VW firmware versions \"05\" to \"07\" allows a local attacker to execute arbitrary code by saving a malicious file to a specific folder. As a result, the attacker may disclose, tamper with, destroy or delete information in the product, or cause a denial-of-service (DoS) condition on the product."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "La vulnerabilidad de permisos predeterminados incorrectos en Smart Device Communication Gateway preinstalado en las versiones de firmware \"05\" a \"07\" de la serie MI5122-VW de MELIPC permite a un atacante local ejecutar c\u00f3digo arbitrario guardando un archivo malicioso en una carpeta espec\u00edfica. Como resultado, el atacante puede revelar, alterar, destruir o eliminar informaci\u00f3n del producto, o provocar una condici\u00f3n de denegaci\u00f3n de servicio (DoS) en el producto."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "CHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 2.0,
|
|
"impactScore": 6.0
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-276"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://jvn.jp/vu/JVNVU91215350/index.html",
|
|
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
|
|
},
|
|
{
|
|
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-02",
|
|
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
|
|
},
|
|
{
|
|
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-003_en.pdf",
|
|
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
|
|
}
|
|
]
|
|
} |