"id": "CVE-2024-6528",
|
|
"sourceIdentifier": "cybersecurity@se.com",
|
|
"published": "2024-07-11T09:15:04.867",
|
|
"lastModified": "2024-07-12T16:37:20.283",
|
|
"vulnStatus": "Analyzed",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site\nScripting') vulnerability exists that could cause a vulnerability leading to a cross-site scripting\ncondition where attackers can have a victim\u2019s browser run arbitrary JavaScript when they visit a\npage containing the injected payload."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "CWE-79: Existe una vulnerabilidad de neutralizaci\u00f3n incorrecta de la entrada durante la generaci\u00f3n de p\u00e1ginas web (\"Cross-site Scripting\") que podr\u00eda causar una vulnerabilidad que conduzca a una condici\u00f3n de cross-site scripting donde los atacantes pueden hacer que el navegador de la v\u00edctima ejecute JavaScript arbitrario cuando visitan una p\u00e1gina que contiene el payload inyectado."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "CHANGED",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "LOW",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 6.1,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 2.7
|
|
},
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "CHANGED",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "LOW",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 5.4,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 2.3,
|
|
"impactScore": 2.7
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-79"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:modicon_m241_firmware:*:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "363D8E9E-0169-472F-A891-EF2E7D329EA2"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:modicon_m241:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "4D8FD9D9-F59F-470E-9F7F-CDDD80B0633C"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:modicon_m251_firmware:*:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "FB11232E-0DC2-436F-985A-94BCE6A4F6D4"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:modicon_m251:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "B8E03A25-B0B6-4BA2-80BC-52C16A6837E0"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:modicon_m258_firmware:*:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "686716B7-1C82-483C-A62F-A33F7C5BF32F"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:modicon_m258:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "FFBF6514-3E32-4C8E-81BA-D6464824351F"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:modicon_m262_firmware:*:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "95E522F5-019E-4948-86D3-B436EEFBAA67"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:modicon_m262:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "F2C151DF-D716-4F2F-8129-9D1B88430A72"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:modicon_lmc058_firmware:*:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "3B05FDCA-D7FB-4931-B058-377B20E1BB1A"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:modicon_lmc058:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "0DFCD3D7-B85B-4C9E-B80C-B83B017183AA"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-191-04.pdf",
|
|
"source": "cybersecurity@se.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |