"lang": "en",
"value": "An improper authorization vulnerability exists in the Rockwell Automation affected products that could allow an unauthorized user to sign in. While removal of all role mappings is unlikely, it could occur in the case of unexpected or accidental removal by the administrator. If exploited, an unauthorized user could access data they previously but should no longer have access to."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de autorizaci\u00f3n indebida en los productos afectados de Rockwell Automation que podr\u00eda permitir que un usuario no autorizado inicie sesi\u00f3n. Si bien es poco probable que se eliminen todas las asignaciones de roles, podr\u00eda ocurrir en caso de que el administrador elimine datos de forma inesperada o accidental. Si se explota, un usuario no autorizado podr\u00eda acceder a datos a los que antes no deber\u00eda tener acceso."
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "HIGH",
"userInteraction": "ACTIVE",
"vulnerableSystemConfidentiality": "HIGH",
"vulnerableSystemIntegrity": "HIGH",
"vulnerableSystemAvailability": "HIGH",
"subsequentSystemConfidentiality": "NONE",
"subsequentSystemIntegrity": "NONE",
"subsequentSystemAvailability": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirements": "NOT_DEFINED",
"integrityRequirements": "NOT_DEFINED",
"availabilityRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
"modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
"modifiedVulnerableSystemAvailability": "NOT_DEFINED",
"modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
"modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
"modifiedSubsequentSystemAvailability": "NOT_DEFINED",
"safety": "NOT_DEFINED",
"automatable": "NOT_DEFINED",
"recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"baseScore": 8.4,
"baseSeverity": "HIGH"
}
}
]
},
"weaknesses": [
{
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-842"
}
]
}
],
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD%201704.html",
"source": "PSIRT@rockwellautomation.com"
}
]
}