2024-12-08 03:06:42 +00:00

120 lines
3.9 KiB
JSON

{
"id": "CVE-2022-22731",
"sourceIdentifier": "cybersecurity@se.com",
"published": "2023-01-30T23:15:09.627",
"lastModified": "2024-11-21T06:47:20.490",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in a function that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause path traversal attacks. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)"
},
{
"lang": "es",
"value": "Existe una vulnerabilidad CWE-22: Limitaci\u00f3n inadecuada de un nombre de ruta a un directorio restringido (\"Path Traversal\") en una funci\u00f3n que podr\u00eda permitir a un atacante crear o sobrescribir archivos cr\u00edticos que se utilizan para ejecutar c\u00f3digo, como programas o librer\u00edas, y causar de Path Traversal. Productos afectados: EcoStruxure Power Commission (versiones anteriores a la V2.22)"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "cybersecurity@se.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "cybersecurity@se.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_commission:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.22",
"matchCriteriaId": "E59BB009-9A61-46F7-BC46-44B4EC678EE4"
}
]
}
]
}
],
"references": [
{
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf",
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Vendor Advisory"
]
},
{
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
]
}
]
}