2024-12-08 03:06:42 +00:00

118 lines
3.6 KiB
JSON

{
"id": "CVE-2022-33925",
"sourceIdentifier": "security_alert@emc.com",
"published": "2022-08-10T17:15:08.817",
"lastModified": "2024-11-21T07:08:37.267",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell Wyse Management Suite 3.6.1 and below contains an Improper Access control vulnerability in UI. An remote authenticated attacker could potentially exploit this vulnerability by bypassing access controls in order to download reports containing sensitive information."
},
{
"lang": "es",
"value": "Dell Wyse Management Suite versiones 3.6.1 y anteriores, contiene una vulnerabilidad de Control de Acceso Inapropiado en la Interfaz de Usuario. Un atacante remoto autenticado podr\u00eda explotar esta vulnerabilidad al omitir los controles de acceso para descargar informes que contengan informaci\u00f3n confidencial"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "security_alert@emc.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
}
]
},
"weaknesses": [
{
"source": "security_alert@emc.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:dell:wyse_management_suite:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.8.0",
"matchCriteriaId": "9A7348AD-CC08-4060-9709-DF24E4AFB092"
}
]
}
]
}
],
"references": [
{
"url": "https://www.dell.com/support/kbdoc/en-us/000201383/dsa-2022-134-dell-wyse-management-suite-security-update-for-multiple-vulnerabilities",
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://www.dell.com/support/kbdoc/en-us/000201383/dsa-2022-134-dell-wyse-management-suite-security-update-for-multiple-vulnerabilities",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}