2024-12-08 03:06:42 +00:00

131 lines
3.7 KiB
JSON

{
"id": "CVE-2022-46025",
"sourceIdentifier": "cve@mitre.org",
"published": "2024-01-10T08:15:37.570",
"lastModified": "2024-11-21T07:30:03.940",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Totolink N200RE_V5 V9.3.5u.6255_B20211224 is vulnerable to Incorrect Access Control. The device allows remote attackers to obtain Wi-Fi system information, such as Wi-Fi SSID and Wi-Fi password, without logging into the management page."
},
{
"lang": "es",
"value": "Totolink N200RE_V5 V9.3.5u.6255_B20211224 es vulnerable a un control de acceso incorrecto. El dispositivo permite a atacantes remotos obtener informaci\u00f3n del sistema Wi-Fi, como el SSID y la contrase\u00f1a de Wi-Fi, sin iniciar sesi\u00f3n en la p\u00e1gina de administraci\u00f3n."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 3.9,
"impactScore": 5.2
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 3.9,
"impactScore": 5.2
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:totolink:n200re_v5_firmware:9.3.5u.6255_b20211224:*:*:*:*:*:*:*",
"matchCriteriaId": "CD83EAD1-6949-4674-8F04-40DCD3FF6833"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:totolink:n200re_v5:-:*:*:*:*:*:*:*",
"matchCriteriaId": "822AE912-4CD8-4015-98DC-AD36A3F2E163"
}
]
}
]
}
],
"references": [
{
"url": "https://pastebin.com/aan5jT40",
"source": "cve@mitre.org",
"tags": [
"Patch",
"Third Party Advisory"
]
},
{
"url": "https://pastebin.com/aan5jT40",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Third Party Advisory"
]
}
]
}