"id": "CVE-2024-22454",
"sourceIdentifier": "security_alert@emc.com",
"published": "2024-02-13T08:16:35.993",
"lastModified": "2024-11-21T08:56:19.273",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\nDell PowerProtect Data Manager, version 19.15 and prior versions, contain a weak password recovery mechanism for forgotten passwords. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to unauthorized access to the application with privileges of the compromised account. The attacker could retrieve the reset password token without authorization and then perform the password change\n\n"
},
{
"lang": "es",
"value": "Dell PowerProtect Data Manager, versi\u00f3n 19.15 y versiones anteriores, contienen un mecanismo de recuperaci\u00f3n de contrase\u00f1as d\u00e9bil para contrase\u00f1as olvidadas. Un atacante remoto no autenticado podr\u00eda explotar esta vulnerabilidad, lo que provocar\u00eda un acceso no autorizado a la aplicaci\u00f3n con privilegios de la cuenta comprometida. El atacante podr\u00eda recuperar el token de restablecimiento de contrase\u00f1a sin autorizaci\u00f3n y luego realizar el cambio de contrase\u00f1a."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "security_alert@emc.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "security_alert@emc.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-640"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:dell:powerprotect_data_manager:*:*:*:*:*:*:*:*",
"versionEndIncluding": "19.15",
"matchCriteriaId": "497410EB-0DE3-4C13-A2EE-C49136E12B33"
}
]
}
]
}
],
"references": [
{
"url": "https://www.dell.com/support/kbdoc/en-us/000222025/dsa-2024-061-dell-power-protect-data-manager-update-for-multiple-security-vulnerabilities",
"source": "security_alert@emc.com",
"tags": [
"Patch",
"Vendor Advisory"
]
},
{
"url": "https://www.dell.com/support/kbdoc/en-us/000222025/dsa-2024-061-dell-power-protect-data-manager-update-for-multiple-security-vulnerabilities",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
]
}
]
}