2025-03-02 03:03:52 +00:00

166 lines
6.0 KiB
JSON

{
"id": "CVE-2024-45467",
"sourceIdentifier": "productcert@siemens.com",
"published": "2024-10-08T09:15:13.180",
"lastModified": "2024-12-10T14:30:42.243",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2302 (todas las versiones anteriores a V2302.0016) y Tecnomatix Plant Simulation V2404 (todas las versiones anteriores a V2404.0005). La aplicaci\u00f3n afectada es vulnerable a la corrupci\u00f3n de memoria al analizar archivos WRL especialmente manipulados. Esto podr\u00eda permitir que un atacante ejecute c\u00f3digo en el contexto del proceso actual."
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "PASSIVE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirement": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"availabilityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
],
"cvssMetricV31": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2302.0016",
"matchCriteriaId": "00AE6AA5-618F-4494-B8D6-2AC25A5DC2F1"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2303.0000",
"versionEndExcluding": "2404.0005",
"matchCriteriaId": "E84CE123-587E-480C-A6C8-AF7B4AE3ACF2"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-583523.html",
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html",
"source": "productcert@siemens.com"
}
]
}