2024-07-14 02:06:08 +00:00

106 lines
3.2 KiB
JSON

{
"id": "CVE-2010-4116",
"sourceIdentifier": "hp-security-alert@hp.com",
"published": "2010-12-22T01:00:02.890",
"lastModified": "2013-07-10T19:57:33.270",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Unspecified vulnerability in HP StorageWorks Storage Mirroring 5.x before 5.2.2.1771.2 allows remote attackers to execute arbitrary code via unknown vectors."
},
{
"lang": "es",
"value": "Vulnerabilidad no especificada en HP StorageWorks Storage Mirroring v5.x anterior v5.2.2.1771.2 permite a atacantes remotos ejecutar c\u00f3digo ejecutable de su elecci\u00f3n a trav\u00e9s de vectores no especificados. \r\n\r\n\r\n"
}
],
"metrics": {
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:hp:storageworks_storage_mirroring:5.0:*:*:*:*:*:*:*",
"matchCriteriaId": "475D5D41-BDD3-411E-8228-9DA5DE3CAC76"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:hp:storageworks_storage_mirroring:5.1:*:*:*:*:*:*:*",
"matchCriteriaId": "CED9F207-885B-45E4-A8FB-1C9604E7D532"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:hp:storageworks_storage_mirroring:5.2:*:*:*:*:*:*:*",
"matchCriteriaId": "91EE5BEC-7FCD-41F8-8FF0-223AF8BCEAF9"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:hp:storageworks_storage_mirroring:5.2.1:*:*:*:*:*:*:*",
"matchCriteriaId": "D6CE9CF1-1FCF-4BDE-97FA-F670AA378A1D"
}
]
}
]
}
],
"references": [
{
"url": "http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c02660122",
"source": "hp-security-alert@hp.com"
},
{
"url": "http://secunia.com/advisories/42696",
"source": "hp-security-alert@hp.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "http://www.securitytracker.com/id?1024916",
"source": "hp-security-alert@hp.com"
}
]
}