"id": "CVE-2021-20074",
"sourceIdentifier": "vulnreport@tenable.com",
"published": "2021-02-16T20:15:16.283",
"lastModified": "2024-11-21T05:45:52.670",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Racom's MIDGE Firmware 4.4.40.105 contains an issue that allows users to escape the provided command line interface and execute arbitrary OS commands."
},
{
"lang": "es",
"value": "El dispositivo MIDGE de Racom versi\u00f3n de Firmware 4.4.40.105, contiene un problema que permite a usuarios escapar de la interfaz de l\u00ednea de comandos proporcionada y ejecutar comandos arbitrarios del Sistema Operativo"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"baseScore": 9.0,
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE"
},
"baseSeverity": "HIGH",
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:racom:m\\!dge_firmware:4.4.40.105:*:*:*:*:*:*:*",
"matchCriteriaId": "779C22FA-7C9D-484E-999E-B1015D0700A5"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:racom:m\\!dge:-:*:*:*:*:*:*:*",
"matchCriteriaId": "421E1B5D-6A4A-47D9-8DEC-990D5C8F060A"
}
]
}
]
}
],
"references": [
{
"url": "https://www.tenable.com/security/research/tra-2021-04",
"source": "vulnreport@tenable.com",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://www.tenable.com/security/research/tra-2021-04",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
]
}
]
}