"lang": "en",
|
|
"value": "The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00)."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "El producto afectado es vulnerable a una escritura fuera de l\u00edmites, lo que puede resultar en una corrupci\u00f3n de datos o una ejecuci\u00f3n de c\u00f3digo de Welch Allyn medical device management tools (Welch Allyn Service Tool: versiones anteriores a v1.10, Welch Allyn Connex Device Integration Suite - Network Connectivity Engine (NCE): versiones anteriores a v5.3, Welch Allyn Software Development Kit (SDK): versiones anteriores a v3.2, Welch Allyn Connex Central Station (CS): versiones anteriores a v1. 8.6, Welch Allyn Service Monitor: versiones anteriores a v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versiones anteriores a v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versiones anteriores a v2. 43.02, Welch Allyn Connex Spot Monitor (CSM): versiones anteriores a v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versiones anteriores a v1.11.00)"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseScore": 9.8,
|
|
"baseSeverity": "CRITICAL",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 5.9
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
|
|
"baseScore": 7.5,
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "PARTIAL",
|
|
"integrityImpact": "PARTIAL",
|
|
"availabilityImpact": "PARTIAL"
|
|
},
|
|
"baseSeverity": "HIGH",
|
|
"exploitabilityScore": 10.0,
|
|
"impactScore": 6.4,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "ics-cert@hq.dhs.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-787"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:hillrom:connex_central_station:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.8.6",
|
|
"matchCriteriaId": "C49585B9-3AA0-42AB-9182-77152BAFA37D"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:hillrom:connex_device_integration_suite_network_connectivity_engine:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "5.3",
|
|
"matchCriteriaId": "5C24A4F7-EEA2-4FA8-9F55-77E1656B2E81"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:hillrom:connex_integrated_wall_system:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "2.43.02",
|
|
"matchCriteriaId": "895DC8BC-529D-4125-A55F-298B70E18007"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:hillrom:connex_spot_monitor:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.52",
|
|
"matchCriteriaId": "DB9BF71D-0C66-4EE0-A25E-44C15A98CF1B"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:hillrom:connex_vital_signs_monitor:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "2.43.02",
|
|
"matchCriteriaId": "D22AECD4-34FE-45D0-AD50-9F1B269578B2"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:hillrom:service_monitor:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.7.0.0",
|
|
"matchCriteriaId": "4D618609-3AE0-47F3-A862-7888C3FBCB98"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:hillrom:service_tool:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.10",
|
|
"matchCriteriaId": "F2B7E63E-27FA-4C03-9039-1F7C47B7A09D"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:hillrom:software_development_kit:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "3.2",
|
|
"matchCriteriaId": "607AE812-A7F3-4705-BF29-2CB3A6B5A91B"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:hillrom:spot_vital_signs_4400:*:*:*:*:-:*:*:*",
|
|
"versionEndExcluding": "1.11.00",
|
|
"matchCriteriaId": "C7CF411D-E942-4807-A0D3-4154514A0E7C"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:hillrom:spot_vital_signs_4400:*:*:*:*:extended_care:*:*:*",
|
|
"versionEndExcluding": "1.11.00",
|
|
"matchCriteriaId": "2BAFF889-0D46-403F-89AA-C61F7DEADE69"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01",
|
|
"source": "ics-cert@hq.dhs.gov",
|
|
"tags": [
|
|
"Mitigation",
|
|
"Third Party Advisory",
|
|
"US Government Resource"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Mitigation",
|
|
"Third Party Advisory",
|
|
"US Government Resource"
|
|
]
|
|
}
|
|
]
|
|
} |