2024-12-08 03:06:42 +00:00

163 lines
5.0 KiB
JSON

{
"id": "CVE-2021-27476",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"published": "2022-03-23T20:15:09.327",
"lastModified": "2024-11-21T05:58:04.187",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in the SaveConfigFile function of the RACompare Service, which may allow for OS command injection. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad en la funci\u00f3n SaveConfigFile del servicio RACompare, que puede permitir una inyecci\u00f3n de comandos del Sistema Operativo. Esta vulnerabilidad puede permitir a un atacante remoto no autenticado ejecutar comandos arbitrarios en Rockwell Automation FactoryTalk AssetCentre versiones v10.00 y anteriores"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:H",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 5.8
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"baseScore": 7.5,
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL"
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_assetcentre:*:*:*:*:*:*:*:*",
"versionEndIncluding": "10.00",
"matchCriteriaId": "B6E37708-7A43-42C7-8BA8-E2731FA55156"
}
]
}
]
}
],
"references": [
{
"url": "https://idp.rockwellautomation.com/adfs/ls/idpinitiatedsignon.aspx?RelayState=RPID%3Drockwellautomation.custhelp.com%26RelayState%3Danswers%2Fanswer_view%2Fa_id%2F1130831",
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Permissions Required",
"Vendor Advisory"
]
},
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-091-01",
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
]
},
{
"url": "https://idp.rockwellautomation.com/adfs/ls/idpinitiatedsignon.aspx?RelayState=RPID%3Drockwellautomation.custhelp.com%26RelayState%3Danswers%2Fanswer_view%2Fa_id%2F1130831",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Permissions Required",
"Vendor Advisory"
]
},
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-091-01",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
]
}
]
}