2024-12-08 03:06:42 +00:00

285 lines
8.2 KiB
JSON

{
"id": "CVE-2021-38518",
"sourceIdentifier": "cve@mitre.org",
"published": "2021-08-11T00:15:35.397",
"lastModified": "2024-11-21T06:17:18.670",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por un usuario autenticado. Esto afecta a RAX200 versiones anteriores a 1.0.4.120, RAX75 versiones anteriores a 1.0.4.120, RAX80 versiones anteriores a 1.0.4.120, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "cve@mitre.org",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.7,
"impactScore": 6.0
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"baseScore": 6.5,
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL"
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.4.120",
"matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.4.120",
"matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.4.120",
"matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*",
"matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.2.17.12",
"matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.2.17.12",
"matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.2.17.12",
"matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52"
}
]
}
]
}
],
"references": [
{
"url": "https://kb.netgear.com/000063783/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0528",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://kb.netgear.com/000063783/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0528",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}