2024-12-08 03:06:42 +00:00

397 lines
11 KiB
JSON

{
"id": "CVE-2021-38530",
"sourceIdentifier": "cve@mitre.org",
"published": "2021-08-11T00:17:02.977",
"lastModified": "2024-11-21T06:17:21.200",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK40 before 2.5.1.16, RBR40 before 2.5.1.16, RBS40 before 2.5.1.16, RBK20 before 2.5.1.16, RBR20 before 2.5.1.16, RBS20 before 2.5.1.16, RBK50 before 2.5.1.16, RBR50 before 2.5.1.16, RBS50 before 2.5.1.16, and RBS50Y before 2.6.1.40."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por un atacante no autenticado. Esto afecta a RBK40 versiones anteriores a 2.5.1.16, RBR40 versiones anteriores a 2.5.1.16, RBS40 versiones anteriores a 2.5.1.16, RBK20 versiones anteriores a 2.5.1.16, RBR20 versiones anteriores a 2.5.1.16, RBS20 versiones anteriores a 2.5.1.16, RBK50 versiones anteriores a 2.5.1.16, RBR50 versiones anteriores a 2.5.1.16, RBS50 versiones anteriores a 2.5.1.16 y RBS50Y versiones anteriores a 2.6.1.40"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "cve@mitre.org",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 6.0
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"baseScore": 10.0,
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE"
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.5.1.16",
"matchCriteriaId": "3DB57ABF-8ABA-47E0-974D-AF8DF696A968"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.5.1.16",
"matchCriteriaId": "DC03D821-0AC5-43F6-B02D-5F858F38DC2E"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbr40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A9E20E59-2B1E-4E43-A494-2C20FD716D4F"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.5.1.16",
"matchCriteriaId": "F725B299-3366-4103-BB4B-CBB7EA4DE2B2"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.5.1.16",
"matchCriteriaId": "AE5AB36A-A020-4604-AB9B-55F114172D8D"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.5.1.16",
"matchCriteriaId": "31604191-2A95-440D-B58B-84066805D623"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.5.1.16",
"matchCriteriaId": "87234D9C-235C-49CB-B88C-C2B84007387B"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.5.1.16",
"matchCriteriaId": "70C4C62E-6B4C-4987-A6CA-07903E37EC34"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.5.1.16",
"matchCriteriaId": "D5C3D18C-1CA3-4082-8F81-03BCE08F88B0"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.5.1.16",
"matchCriteriaId": "1EA2BB79-FBC6-45FB-B617-7EFCEE57DB73"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbs50y_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.6.1.40",
"matchCriteriaId": "E9E75105-CB35-4983-8CC0-98699AAA63BE"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbs50y:-:*:*:*:*:*:*:*",
"matchCriteriaId": "27F93A76-6EFF-4DA6-9129-4792E2C125D4"
}
]
}
]
}
],
"references": [
{
"url": "https://kb.netgear.com/000063770/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2019-0151",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://kb.netgear.com/000063770/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2019-0151",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}