mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 09:11:28 +00:00
127 lines
5.0 KiB
JSON
127 lines
5.0 KiB
JSON
{
|
|
"id": "CVE-2021-38543",
|
|
"sourceIdentifier": "cve@mitre.org",
|
|
"published": "2021-08-11T16:15:07.210",
|
|
"lastModified": "2024-11-21T06:17:23.650",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "TP-Link UE330 USB splitter devices through 2021-08-09, in certain specific use cases in which the device supplies power to audio-output equipment, allow remote attackers to recover speech signals from an LED on the device, via a telescope and an electro-optical sensor, aka a \"Glowworm\" attack. We assume that the USB splitter supplies power to some speakers. The power indicator LED of the USB splitter is connected directly to the power line, as a result, the intensity of the USB splitter's power indicator LED is correlative to its power consumption. The sound played by the connected speakers affects the USB splitter's power consumption and as a result is also correlative to the light intensity of the LED. By analyzing measurements obtained from an electro-optical sensor directed at the power indicator LED of the USB splitter, we can recover the sound played by the connected speakers."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Los dispositivos splitter USB TP-Link UE330 hasta 09-08-2021, en determinados casos de uso en los que el dispositivo suministra energ\u00eda a equipos de salida de audio, permiten a atacantes remotos recuperar las se\u00f1ales de voz de un LED del dispositivo, por medio de un telescopio y un sensor electro-\u00f3ptico, tambi\u00e9n se conoce como un ataque \"Glowworm\". Suponemos que el divisor USB suministra energ\u00eda a unos altavoces. El LED indicador de potencia del divisor USB est\u00e1 conectado directamente a la l\u00ednea de alimentaci\u00f3n, por lo que la intensidad del LED indicador de potencia del divisor USB es correlativa a su consumo de energ\u00eda. El sonido reproducido por los altavoces conectados afecta al consumo de energ\u00eda del divisor USB y, en consecuencia, tambi\u00e9n es correlativo a la intensidad luminosa del LED. Al analizar las medidas obtenidas por un sensor electro-\u00f3ptico dirigido al LED indicador de potencia del splitter USB, podemos recuperar el sonido reproducido por los altavoces conectados"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
|
|
"baseScore": 5.9,
|
|
"baseSeverity": "MEDIUM",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "HIGH",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE"
|
|
},
|
|
"exploitabilityScore": 2.2,
|
|
"impactScore": 3.6
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
|
|
"baseScore": 4.3,
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "MEDIUM",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "PARTIAL",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE"
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 8.6,
|
|
"impactScore": 2.9,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "NVD-CWE-noinfo"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:tp-link:ue330_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "2021-08-09",
|
|
"matchCriteriaId": "5AF9B484-A232-4F75-BB17-1433C4C346B4"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:tp-link:ue330:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "0D0B23AE-60C1-404A-94D7-55FD0A340F37"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.nassiben.com/glowworm-attack",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Exploit",
|
|
"Third Party Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.nassiben.com/glowworm-attack",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Exploit",
|
|
"Third Party Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |