"id": "CVE-2021-40661",
|
|
"sourceIdentifier": "cve@mitre.org",
|
|
"published": "2022-10-31T12:15:10.057",
|
|
"lastModified": "2024-11-21T06:24:32.267",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A remote, unauthenticated, directory traversal vulnerability was identified within the web interface used by IND780 Advanced Weighing Terminals Build 8.0.07 March 19, 2018 (SS Label 'IND780_8.0.07'), Version 7.2.10 June 18, 2012 (SS Label 'IND780_7.2.10'). It was possible to traverse the folders of the affected host by providing a traversal path to the 'webpage' parameter in AutoCE.ini This could allow a remote unauthenticated adversary to access additional files on the affected system. This could also allow the adversary to perform further enumeration against the affected host to identify the versions of the systems in use, in order to launch further attacks in future."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se identific\u00f3 una vulnerabilidad de Directory Traversal no autenticada dentro de la interfaz web utilizada por IND780 Advanced Weighing Terminals Build 8.0.07 March 19, 2018 (SS Label 'IND780_8.0.07'), Version 7.2.10 June 18, 2012 (SS Label 'IND780_7.2.10'). Era posible atravesar las carpetas del anfitri\u00f3n afectado proporcionando una Path Traversal al par\u00e1metro 'p\u00e1gina web' en AutoCE.ini. Esto podr\u00eda permitir que un adversario remoto no autenticado acceda a archivos adicionales en el sistema afectado. Esto tambi\u00e9n podr\u00eda permitir al adversario realizar una enumeraci\u00f3n adicional del anfitri\u00f3n afectado para identificar las versiones de los sistemas en uso, con el fin de lanzar m\u00e1s ataques en el futuro."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
|
|
"baseScore": 7.5,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 3.6
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-22"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:mt:ind780_firmware:7.2.10:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "DA98C6CD-D293-42D6-A284-2AEBAAF2D6F7"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:mt:ind780_firmware:8.0.07:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "8D4E05C4-ED84-4F63-9C72-0D881DC2CB0C"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:mt:ind780:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "B788AAB0-6AF4-41F1-80E5-C0D595C2804D"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://sidsecure.au/blog/cve-2021-40661/?_sm_pdc=1&_sm_rid=MRRqb4KBDnjBMJk24b40LMS3SKqPMqb4KVn32Kr",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Exploit",
|
|
"Third Party Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.mt.com/au/en/home/products/Industrial_Weighing_Solutions/Terminals-and-Controllers/terminals-bench-floor-scales/advanced-bench-floor-applications/IND780/IND780_.html#overviewpm",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Product",
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://sidsecure.au/blog/cve-2021-40661/?_sm_pdc=1&_sm_rid=MRRqb4KBDnjBMJk24b40LMS3SKqPMqb4KVn32Kr",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Exploit",
|
|
"Third Party Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.mt.com/au/en/home/products/Industrial_Weighing_Solutions/Terminals-and-Controllers/terminals-bench-floor-scales/advanced-bench-floor-applications/IND780/IND780_.html#overviewpm",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Product",
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |