2024-12-08 03:06:42 +00:00

369 lines
11 KiB
JSON

{
"id": "CVE-2021-45533",
"sourceIdentifier": "cve@mitre.org",
"published": "2021-12-26T01:15:14.553",
"lastModified": "2024-11-21T06:32:26.620",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects EX6120 before 1.0.0.66, EX6130 before 1.0.0.46, EX7000 before 1.0.1.106, EX7500 before 1.0.1.76, EX3700 before 1.0.0.94, EX3800 before 1.0.0.94, RBR850 before 4.6.3.9, RBS850 before 4.6.3.9, and RBK852 before 4.6.3.9."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a los dispositivos EX6120 versiones anteriores a 1.0.0.66, EX6130 versiones anteriores a 1.0.0.46, EX7000 versiones anteriores a 1.0.1.106, EX7500 versiones anteriores a 1.0.1.76, EX3700 versiones anteriores a 1.0.0.94, EX3800 versiones anteriores a 1.0.0.94, RBR850 versiones anteriores a 4.6.3.9, RBS850 versiones anteriores a 4.6.3.9 y RBK852 versiones anteriores a 4.6.3.9"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "cve@mitre.org",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.7,
"impactScore": 6.0
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 0.9,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
"baseScore": 5.2,
"accessVector": "ADJACENT_NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL"
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 5.1,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.0.66",
"matchCriteriaId": "8ECBE89E-3C81-470A-80C0-F742D7ABC66D"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.0.46",
"matchCriteriaId": "4D32948E-0E3F-4F1E-9BF8-AA159659B248"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*",
"matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.1.106",
"matchCriteriaId": "C2D1A25A-22F9-49BF-8335-61EC6D0D1951"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9F45B620-60B8-40F3-A055-181ADD71EFFF"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.1.76",
"matchCriteriaId": "CAFA0844-677F-4753-9289-DFEB4B59D689"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.0.94",
"matchCriteriaId": "A65EE9FC-A015-4D92-8DA3-40C8594D843D"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.0.94",
"matchCriteriaId": "ED72FFCA-F5A8-480D-8A29-C14FFC490B33"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.6.3.9",
"matchCriteriaId": "532EF10D-71E1-476B-A9EA-4454F2BB9B34"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.6.3.9",
"matchCriteriaId": "7C2F2D01-7924-42D2-A07E-15AB1D37810F"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.6.3.9",
"matchCriteriaId": "0772693C-678C-4AB3-9E7B-D2B4DB7770D9"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7"
}
]
}
]
}
],
"references": [
{
"url": "https://kb.netgear.com/000064458/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0062",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://kb.netgear.com/000064458/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0062",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}