2024-12-08 03:06:42 +00:00

369 lines
10 KiB
JSON

{
"id": "CVE-2021-45593",
"sourceIdentifier": "cve@mitre.org",
"published": "2021-12-26T01:15:17.397",
"lastModified": "2024-11-21T06:32:36.857",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBR20 before 2.7.3.22, RBR40 before 2.7.3.22, RBR50 before 2.7.2.102, RBS20 before 2.7.3.22, RBS40 before 2.7.3.22, RBR50 before 2.7.2.102, RBK20 before 2.7.3.22, RBK40 before 2.7.3.22, and RBK50 before 2.7.2.102."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBR20 versiones anteriores a 2.7.3.22, RBR40 versiones anteriores a 2.7.3.22, RBR50 versiones anteriores a 2.7.2.102, RBS20 versiones anteriores a 2.7.3.22, RBS40 versiones anteriores a 2.7.3.22, RBR50 versiones anteriores a 2.7.2.102, RBK20 versiones anteriores a 2.7.3.22, RBK40 versiones anteriores a 2.7.3.22 y RBK50 versiones anteriores a 2.7.2.102"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "cve@mitre.org",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.7,
"impactScore": 6.0
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 0.9,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
"baseScore": 5.2,
"accessVector": "ADJACENT_NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL"
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 5.1,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.7.3.22",
"matchCriteriaId": "4E0AC598-D991-49E0-86ED-4ABF0E42E504"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.7.3.22",
"matchCriteriaId": "1FD3226E-1B9D-420E-AD7B-7D1DDC867D3F"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbr40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A9E20E59-2B1E-4E43-A494-2C20FD716D4F"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.7.2.102",
"matchCriteriaId": "BDB4D475-D18E-4555-A4B5-2664DC4122CB"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.7.3.22",
"matchCriteriaId": "3C936668-6B8C-4497-A5A3-7C4B6CADB09B"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.7.3.22",
"matchCriteriaId": "40435599-FC79-4563-BF8B-BB1F84BDA82D"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.7.2.102",
"matchCriteriaId": "BDB4D475-D18E-4555-A4B5-2664DC4122CB"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.7.3.22",
"matchCriteriaId": "A4021DFA-AEBD-4C6C-9793-48171990F8B3"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.7.3.22",
"matchCriteriaId": "CA096BE4-3AE5-4AEA-B4C4-359D3A0C7F1E"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.7.2.102",
"matchCriteriaId": "771892CD-B68B-4EC7-986D-778A8DE83078"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B"
}
]
}
]
}
],
"references": [
{
"url": "https://kb.netgear.com/000064474/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0175",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://kb.netgear.com/000064474/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0175",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}